When mission-critical facilities face arctic winters, scorching summers, or simultaneous heating/cooling needs, off-the-shelf heat pumps fail. KLR GROUP redefines resilience with the Titan Inverter EVI Heating/Cooling Heat Pump—an engineering titan built on military-proven EVI tech, delivering uncompromised performance where others shut down.
Enhanced Vapor Injection (EVI) technology supercharges Titan’s capabilities:
100% Heating Output at -25°C: No backup electric strips needed (vs. 40% capacity loss in standard units).
Cascaded Inverter Compressors: Dual rotary compressors share load for 100,000+ hour lifespans.
Jet-Frost Defrost: 90-second ice removal without temperature drop.
Validated at Canada’s Northern Research Institute (NRI) -30°C Arctic Chamber.

Titan’s TriFlow™ System serves three demands in one cycle (e.g., warm pools while chilling data centers):
| Mode | Industry Application |
|---|---|
| Heating Only | Snow melt systems, process tanks |
| Cooling Only | Server rooms, manufacturing lines |
| Heat Recovery | Pool heating + AC for clubhouses |
Ultra-Low GWP (573): Meets 2030 EU F-Gas Phase-Down targets.
Non-Flammable (A1): ASHRAE Safety Class A1 for confined spaces.
40% Higher Heat Transfer vs. R134a in subzero conditions.
| Model | Heating Capacity (kW) | Cooling Capacity (kW) | COP/EER | Ambient Range |
|---|---|---|---|---|
| TITAN-40 | 40 (-25°C) / 52 (7°C) | 38 (50°C) / 48 (35°C) | COP 3.8 / EER 4.2 | -25°C to 55°C |
| TITAN-80 | 80 (-25°C) / 104 (7°C) | 76 (50°C) / 96 (35°C) | COP 3.6 / EER 4.0 | -25°C to 55°C |
| TITAN-120 | 120 (-25°C) / 156 (7°C) | 114 (50°C) / 144 (35°C) | COP 3.5 / EER 3.8 | -25°C to 55°C |
Heating COP at -7°C DB/WB | Cooling EER at 35°C DB/26°C WB (AHRI 210/240)
Vibration Dampers: 85% shock absorption for earthquake zones (IBC 2018 compliant).
Corrosion Armor: IP55 enclosure + stainless steel louver fins (ISO 9227 salt spray certified).
CyberLock™ Controls: Air-gapped system with physical key override.
MODBUS/BACnet Integration: Central BMS monitoring via Siemens/Johnson Controls.
Predictive Analytics: AI forecasts compressor wear 200+ hours pre-failure.
Dual-Circuit Redundancy: Auto-switch to backup circuit during faults.
No Derating Policy: Full capacity from -25°C to 55°C (industry-first guarantee).
20-Year Design Life: 2x industry average for commercial units.
Carbon Neutral Manufacturing: Powered by on-site solar/wind at KLR GROUP plants.
Deploy Unbreakable Climate Control
→ Case Study: How Titan Powers Arctic Mining Camps
→ TCO Calculator: Compare 10-Year Savings vs. Gas Boilers + Chillers
→ Commissioning Kit: Request Site Survey & Load Plan